| Model Name |
: |
MIXSED |
| Model Code |
: |
MS-020 |
| Area of Application |
: |
Fully automatic erythrocyte sedimentation rate analysis (ESR) with integrated sample mixing (homogenization) prior to testing |
| Analysis Time |
: |
12 min. / 20 min. / *40 min. *
(to obtain 2nd hour results in normal operating method) |
| Analysis Methods & Reading System |
: |
Normal operating method vertical, fast operating
method using tube inclination, IR-transmission
reading directly from vacuum blood collection tube |
| Automatic Mixing |
: |
Three selectable mixing cycles: 5, 8 or 12 minutes |
| Analytical Capacity (inclusive 5 min. mixing cycle selection) |
: |
Max. 70 tests/h in 12 min. mode |
Max. 48 tests/h in 20 min. mode |
| Reading Channels Access |
: |
20 - independently and simultaneously operating
(using random loading or batch loading mode) |
| Measuring Method |
: |
Westergren applying infrared barrier |
| Loading Capacity & Pattern |
: |
Max. 20 samples
(in batch loading mode or random loading mode) |
| Analysis Results |
: |
Converted into Westergren mm/h (by interpolation)
with 30 minutes, 1 hour & 2 hours results |
| Measuring Range |
: |
1 to 140 mm/h. Higher values are marked |
| Temperature Correction |
: |
Automatic compensation referred to 18°C
applying the Manley table |
| Reading Resolution |
: |
+/– 0.1 mm |
| Results Resolution |
: |
+/– 0.5 mm |
| Blood Draw Requirement |
: |
PLASED 100 tube using 1.0 ml draw,
PLASED 120 tube for 1.2 ml draw |
| Blood Draw Acceptance Level |
: |
+/– 5 mm from normal, automatic monitoring
and error level information |
| Operating Information During Analysis |
: |
Status of operations, remaining time
indication & error information |
| Reproducibility of Analysis |
: |
C.V. < 3% |
| Operator Interface: Display Panel |
: |
Alphanumeric mono LCD with 2 rows of 40 characters each |
| Output Interface |
: |
Printer mode |
| External Memory |
: |
I2C BUS connector |
| Operating Conditions |
: |
Room temperature: 15 to 35°C /
Humidity: 45 to 85%, not condensed |
| Power Supply Voltage |
: |
AC 110-240 V, 50/60 Hz |
| Operating Voltage (Input) |
: |
DC 18-19 V, 1.6 A |
| Conformity |
: |
IVD Directive 98/79/EC, EMC Directive 89/336/EEC,
Low Voltage Directive 73/23/EEC, CE Marking |
Instrument Dimension
[H x W x D] mm |
: |
330 x 320 x 200 |
Carton Box Dimension
[H x W x D] mm |
: |
380 x 375 x 258 |
| Gross / Nett Weight |
: |
4.2 Kgs / 2.8 Kgs |
** All Specifications are correct at time of print and are subject to change without notice. |